Assessment Year | 2024 |
---|---|
Principal Product | wastewater treatment |
NAICS | 221320: Sewage Treatment Facilities |
SIC | 4952: Sewerage Systems |
Sales Range | $1 M to 5M |
# of Employees | 3 |
Plant Area |
10,000
ft2
|
Annual Production | 129,125
Tgal
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $102,027 | 1,507,748 |
kWh
|
$0.068 |
Electricity Demand | $12,740 | 3,197 |
kW-mo/yr
|
$3.98 |
Electricity Fees | $16,065 | - |
|
- |
TOTAL YEARLY COSTS | $130,832 | |||
RECOMMENDED SAVINGS* | $20,696 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.6231: Utilize controls to operate equipment only when needed | $8,211 | $64,000 |
$8,211
120,750
kWh
|
|
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $10,139 | $51,000 |
$10,139
149,100
kWh
|
|
03 | 3.1161: Eliminate/reduce an operation | $2,346 | $520 |
$2,346
34,500
kWh
|
|
TOTAL RECOMMENDED | $20,696 | $115,520 |
$20,696
304,350
kWh
|
||
TOTAL IMPLEMENTED | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs