Assessment Year | 2021 |
---|---|
Principal Product | Metal Containers |
NAICS | 332420: Metal Tank (Heavy Gauge) Manufacturing |
SIC | 3443: Fabricated Plate Work (Boiler Shops) |
Sales Range | $10 M to 50M |
# of Employees | 160 |
Plant Area |
95,500
ft2
|
Annual Production | 2,525
units
|
Production Hrs. Annual | 5,325
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $142,641 | 2,177,232 |
kWh
|
$0.066 | |
Electricity Demand | $29,394 | 6,011 |
kW-mo/yr
|
$4.89 | |
Natural Gas | $61,575 | 13,004 |
MMBtu
|
$4.74 | |
Waste Disposal Costs | |||||
Water Usage | $15,817 | 1,014 |
Tgal
|
$15.61 | |
TOTAL YEARLY COSTS | $249,427 | ||||
RECOMMENDED SAVINGS* | $95,467 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $48,747 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2211: Use optimum temperature | $8,560 | - | - |
$8,560
-
MMBtu
|
|
02 | 2.7131: Add area lighting switches | $21,520 | $846 |
$21,520
272,431
kWh
|
- | |
03 | 2.7221: Lower temperature during the winter season and vice-versa | $9,710 | - | - |
$9,710
-
MMBtu
|
|
04 | 2.7261: Install timers and/or thermostats | $730 | $135 |
$730
9,230
kWh
|
- | |
05 | 2.2443: Re-use or recycle hot or cold process exhaust air | $2,034 | $1,300 | - |
$2,034
-
MMBtu
|
|
06 | 2.4322: Use or replace with energy efficient substitutes | $12,960 | $173,544 |
$12,960
164,000
kWh
|
- | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,810 | $1,098 |
$1,810
22,900
kWh
|
- | |
08 | 2.1224: Replace boiler | $8,560 | $23,609 | - |
$8,560
-
MMBtu
|
|
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $23,313 | $39,529 |
$23,313
295,106
kWh
|
- | |
10 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $1,950 | $9,070 | - |
$1,950
-
MMBtu
|
|
11 | 2.7232: Replace existing hvac unit with high efficiency model | $4,320 | $14,125 | - |
$4,320
-
MMBtu
|
|
TOTAL RECOMMENDED | $95,467 | $263,256 |
$60,333
763,667
kWh
|
$35,134
-
MMBtu
|
||
TOTAL IMPLEMENTED | $48,747 | $214,508 |
$37,003
468,336
kWh
|
$11,744
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |