Assessment Year 2020
Principal Product Precision Measuring Equipment
NAICS 334519: Other Measuring and Controlling Device Manufacturing
SIC 3829: Measuring and Controlling Devices, Not Elsewhere Classified
Sales Range $100
M
to 500
M
# of Employees 275
Plant Area 210,000
ft2
Annual Production 2,500
units
Production Hrs. Annual 3,000
hrs
Location (State) Delaware

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $334,194 5,498,100
kWh
Electricity Demand $200,427 10,838
kW-mo/yr
Electricity Fees $1,800 -
Natural Gas $24,159 2,962
MMBtu
Waste Disposal Costs
Water Usage $32,140 5,592
Tgal
TOTAL YEARLY COSTS $592,720
RECOMMENDED SAVINGS* $97,620 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $88,110

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown $32,510 - $32,510
532,950
kWh
-
02 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown $2,480 $1,500 $1,010
16,500
kWh
$1,470
-
MMBtu
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $4,540 $10,000 $4,540
46,830
kWh
-
04 2.4224: Upgrade controls on compressors $4,970 $6,500 $4,970
51,300
kWh
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $47,490 $87,516 $47,490
489,600
kWh
-
06 2.7142: Utilize higher efficiency lamps and/or ballasts $2,150 $3,146 $2,150
35,300
kWh
-
07 2.2437: Recover waste heat from equipment $3,480 $10,375 - $3,480
-
MMBtu
TOTAL RECOMMENDED $97,620 $119,037 $92,670
1,172,480
kWh
$4,950
-
MMBtu
TOTAL IMPLEMENTED $88,110 $102,537 $83,160
1,074,350
kWh
$4,950
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs