Assessment Year | 2020 |
---|---|
Principal Product | Precision Measuring Equipment |
NAICS | 334519: Other Measuring and Controlling Device Manufacturing |
SIC | 3829: Measuring and Controlling Devices, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 275 |
Plant Area |
210,000
ft2
|
Annual Production | 2,500
units
|
Production Hrs. Annual | 3,000
hrs
|
Location (State) | Delaware |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $334,194 | 5,498,100 |
kWh
|
$0.061 | |
Electricity Demand | $200,427 | 10,838 |
kW-mo/yr
|
$18.49 | |
Electricity Fees | $1,800 | - |
|
- | |
Natural Gas | $24,159 | 2,962 |
MMBtu
|
$8.16 | |
Waste Disposal Costs | |||||
Water Usage | $32,140 | 5,592 |
Tgal
|
$5.75 | |
TOTAL YEARLY COSTS | $592,720 | ||||
RECOMMENDED SAVINGS* | $97,620 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $88,110 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown | $32,510 | - |
$32,510
532,950
kWh
|
- | |
02 | 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown | $2,480 | $1,500 |
$1,010
16,500
kWh
|
$1,470
-
MMBtu
|
|
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,540 | $10,000 |
$4,540
46,830
kWh
|
- | |
04 | 2.4224: Upgrade controls on compressors | $4,970 | $6,500 |
$4,970
51,300
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $47,490 | $87,516 |
$47,490
489,600
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,150 | $3,146 |
$2,150
35,300
kWh
|
- | |
07 | 2.2437: Recover waste heat from equipment | $3,480 | $10,375 | - |
$3,480
-
MMBtu
|
|
TOTAL RECOMMENDED | $97,620 | $119,037 |
$92,670
1,172,480
kWh
|
$4,950
-
MMBtu
|
||
TOTAL IMPLEMENTED | $88,110 | $102,537 |
$83,160
1,074,350
kWh
|
$4,950
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs