Assessment Year | 2016 |
---|---|
Principal Product | Latex Paints |
NAICS | 325510: Paint and Coating Manufacturing |
SIC | 2851: Paints, Varnishes, Lacquers, Enamels, and Allied Products |
Sales Range | $100 M to 500M |
# of Employees | 110 |
Plant Area |
254,800
ft2
|
Annual Production | 12,000
Tgal
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Delaware |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $358,733 | 4,959,127 |
kWh
|
$0.072 |
Natural Gas | $18,801 | 2,009 |
MMBtu
|
$9.36 |
TOTAL YEARLY COSTS | $377,534 | |||
RECOMMENDED SAVINGS* | $39,745 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4224: Upgrade controls on compressors | $12,960 | $23,000 |
$12,960
180,000
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,055 | $40,740 |
$15,055
209,105
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,950 | $9,830 |
$2,950
40,925
kWh
|
|
04 | 2.9114: Use solar heat to make electricty | $8,780 | $47,412 |
$8,780
122,000
kWh
|
|
TOTAL RECOMMENDED | $39,745 | $120,982 |
$39,745
552,030
kWh
|
||
TOTAL IMPLEMENTED | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs