| Assessment Year | 2016 |
|---|---|
| Principal Product | Latex Paints |
| NAICS | 325510: Paint and Coating Manufacturing |
| SIC | 2851: Paints, Varnishes, Lacquers, Enamels, and Allied Products |
| Sales Range | $100 M to 500M |
| # of Employees | 110 |
| Plant Area |
254,800
ft2
|
| Annual Production | 12,000
Tgal
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Delaware |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $358,733 | 4,959,127 |
kWh
|
$0.072 |
| Natural Gas | $18,801 | 2,009 |
MMBtu
|
$9.36 |
| TOTAL YEARLY COSTS | $377,534 | |||
| RECOMMENDED SAVINGS* | $39,745 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4224: Upgrade controls on compressors | $12,960 | $23,000 |
$12,960
180,000
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,055 | $40,740 |
$15,055
209,105
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,950 | $9,830 |
$2,950
40,925
kWh
|
|
| 04 | 2.9114: Use solar heat to make electricty | $8,780 | $47,412 |
$8,780
122,000
kWh
|
|
| TOTAL RECOMMENDED | $39,745 | $120,982 |
$39,745
552,030
kWh
|
||
| TOTAL IMPLEMENTED | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs