Assessment Year | 2015 |
---|---|
Principal Product | Machined Parts |
NAICS | 332721: Precision Turned Product Manufacturing |
SIC | 3451: Screw Machine Products |
Sales Range | $10 M to 50M |
# of Employees | 40 |
Plant Area |
37,000
ft2
|
Annual Production | 2,200,000
pieces
|
Production Hrs. Annual | 5,195
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $73,209 | 796,320 |
kWh
|
$0.092 |
Electricity Demand | $11,547 | 2,248 |
kW-mo/yr
|
$5.14 |
Electricity Fees | $1,254 | - |
|
- |
LPG | $6,465 | 312 |
MMBtu
|
$20.72 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $35,755 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,925 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings |
---|---|---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $1,950 | $2,280 | - | - |
$1,950
-
MMBtu
|
|
02 | 2.4227: Use compressor air filters | $1,390 | $2,190 |
$1,250
13,540
kWh
|
$140
-
kW-mo/yr
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,250 | $17,060 |
$6,380
69,380
kWh
|
$870
-
kW-mo/yr
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $700 | $2,210 |
$700
7,625
kWh
|
- | - | |
05 | 2.7232: Replace existing hvac unit with high efficiency model | $1,565 | $7,125 |
$1,390
15,060
kWh
|
$175
-
kW-mo/yr
|
- | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,585 | $32,700 |
$4,115
44,720
kWh
|
$470
-
kW-mo/yr
|
- | |
07 | 2.9114: Use solar heat to make electricty | $18,315 | $226,000 |
$18,315
199,075
kWh
|
- | - | |
TOTAL RECOMMENDED | $35,755 | $289,565 |
$32,150
349,400
kWh
|
$1,655
-
kW-mo/yr
|
$1,950
-
MMBtu
|
||
TOTAL IMPLEMENTED | $7,925 | $37,170 |
$5,365
58,260
kWh
|
$610
-
kW-mo/yr
|
$1,950
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs