Assessment Year 2015
Principal Product Licorice Extract
NAICS 311340: Nonchocolate Confectionery Manufacturing
SIC 2064: Candy and Other Confectionery Products
Sales Range $100
M
to 500
M
# of Employees 140
Plant Area 390,000
ft2
Annual Production 6,000
ton
Production Hrs. Annual 6,762
hrs
Location (State) New Jersey

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $676,179 8,016,000
kWh
Electricity Demand $70,872 46,192
kW-mo/yr
Electricity Fees $195,923 -
Natural Gas $1,275,680 207,657
MMBtu
Fuel Oil #1 $240,128 8,960
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $379,525 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $171,145

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.2511: Insulate bare equipment $165,235 $79,620 - $165,235
-
MMBtu
02 2.7231: Use radiant heater for spot heating $81,150 - - $81,150
-
MMBtu
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $65,410 $20,000 $65,410
554,340
kWh
-
04 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $11,355 $7,475 $11,355
96,230
kWh
-
05 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $12,660 $19,415 $12,660
107,260
kWh
-
06 2.6231: Utilize controls to operate equipment only when needed $4,465 $650 $3,240
27,430
kWh
$1,225
-
MMBtu
07 2.2437: Recover waste heat from equipment $5,870 $1,700 - $5,870
-
MMBtu
08 2.6218: Turn off equipment when not in use $6,480 - $6,480
77,180
kWh
-
09 2.7142: Utilize higher efficiency lamps and/or ballasts $11,280 $61,980 $11,280
95,590
kWh
-
10 2.7142: Utilize higher efficiency lamps and/or ballasts $5,645 $13,720 $5,645
51,650
kWh
-
11 2.7142: Utilize higher efficiency lamps and/or ballasts $7,660 $21,550 $7,660
64,910
kWh
-
12 2.7226: Use computer programs to optimize hvac performance $2,315 - $2,315
19,620
kWh
-
TOTAL RECOMMENDED $379,525 $226,110 $126,045
1,094,210
kWh
$253,480
-
MMBtu
TOTAL IMPLEMENTED $171,145 $117,250 $89,995
766,490
kWh
$81,150
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs