Assessment Year 2013
Principal Product Wire cloth, metal belting
NAICS 332618: Other Fabricated Wire Product Manufacturing
SIC 3496: Miscellaneous Fabricated Wire Products
Sales Range $50
M
to 100
M
# of Employees 50
Plant Area 346,000
ft2
Annual Production 9,999
units
Production Hrs. Annual 6,000
hrs
Location (State) Maryland

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $346,133 5,069,553
kWh
Electricity Demand $68,457 12,758
kW-mo/yr
LPG $45,433 2,564
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $118,501 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings LPG Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $7,410 $2,000 $7,410
88,223
kWh
- -
02 2.2437: Recover waste heat from equipment $12,684 $2,350 - - $12,684
-
MMBtu
03 2.2437: Recover waste heat from equipment $11,278 $2,350 $11,278
134,260
kWh
- -
04 2.4231: Reduce the pressure of compressed air to the minimum required $2,080 $500 $2,080
24,774
kWh
- -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $5,930 $2,000 $5,930
70,577
kWh
- -
06 2.1332: Convert combustion equipment to burn natural gas $27,486 $11,000 - $(-17,948.0)
-
MMBtu
$45,434
-
MMBtu
07 2.7444: Close holes and openings in building such as broken windows $10,394 $7,600 $10,394
123,739
kWh
- -
08 2.7134: Use photocell controls $100 $85 $100
1,190
kWh
- -
09 2.1311: Replace electrically-operated equipment with fossil fuel equipment $41,139 $70,800 $63,840
760,000
kWh
$(-22,701.0)
-
MMBtu
-
TOTAL RECOMMENDED $118,501 $98,685 $101,032
1,202,763
kWh
$(-40,649.0)
-
MMBtu
$58,118
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings LPG Savings