| Assessment Year | 2012 |
|---|---|
| Principal Product | Silicon and Boron Carbide Composite |
| NAICS | 339999: All Other Miscellaneous Manufacturing |
| SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 45 |
| Plant Area |
60,000
ft2
|
| Annual Production | 12,000,000
units
|
| Production Hrs. Annual | 4,380
hrs
|
| Location (State) | Delaware |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $908,507 | 11,525,766 |
kWh
|
$0.079 |
| Natural Gas | $53,724 | 3,860 |
MMBtu
|
$13.92 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $225,943 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $145,965 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.6218: Turn off equipment when not in use | $42,739 | $100 |
$42,739
541,000
kWh
|
- | |
| 02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $50,290 | $23,500 |
$50,290
636,587
kWh
|
- | |
| 03 | 2.7124: Make a practice of turning off lights when not needed | $19,620 | $7,000 |
$19,620
248,390
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $21,488 | $34,800 |
$21,488
272,000
kWh
|
- | |
| 05 | 2.7221: Lower temperature during the winter season and vice-versa | $39,912 | $100 |
$10,112
128,000
kWh
|
$29,800
-
MMBtu
|
|
| 06 | 2.4226: Use / purchase optimum sized compressor | $20,935 | $24,500 |
$20,935
265,000
kWh
|
- | |
| 07 | 2.6218: Turn off equipment when not in use | $7,749 | $100 |
$7,749
98,092
kWh
|
- | |
| 08 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $15,010 | $11,800 |
$15,010
190,000
kWh
|
- | |
| 09 | 2.2511: Insulate bare equipment | $8,200 | $1,500 |
$8,200
103,800
kWh
|
- | |
| TOTAL RECOMMENDED | $225,943 | $103,400 |
$196,143
2,482,869
kWh
|
$29,800
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $145,965 | $43,600 |
$116,165
1,470,482
kWh
|
$29,800
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs