Assessment Year | 2012 |
---|---|
Principal Product | Silicon and Boron Carbide Composite |
NAICS | 339999: All Other Miscellaneous Manufacturing |
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 45 |
Plant Area |
60,000
ft2
|
Annual Production | 12,000,000
units
|
Production Hrs. Annual | 4,380
hrs
|
Location (State) | Delaware |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $908,507 | 11,525,766 |
kWh
|
$0.079 |
Natural Gas | $53,724 | 3,860 |
MMBtu
|
$13.92 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $225,943 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $145,965 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $42,739 | $100 |
$42,739
541,000
kWh
|
- | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $50,290 | $23,500 |
$50,290
636,587
kWh
|
- | |
03 | 2.7124: Make a practice of turning off lights when not needed | $19,620 | $7,000 |
$19,620
248,390
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $21,488 | $34,800 |
$21,488
272,000
kWh
|
- | |
05 | 2.7221: Lower temperature during the winter season and vice-versa | $39,912 | $100 |
$10,112
128,000
kWh
|
$29,800
-
MMBtu
|
|
06 | 2.4226: Use / purchase optimum sized compressor | $20,935 | $24,500 |
$20,935
265,000
kWh
|
- | |
07 | 2.6218: Turn off equipment when not in use | $7,749 | $100 |
$7,749
98,092
kWh
|
- | |
08 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $15,010 | $11,800 |
$15,010
190,000
kWh
|
- | |
09 | 2.2511: Insulate bare equipment | $8,200 | $1,500 |
$8,200
103,800
kWh
|
- | |
TOTAL RECOMMENDED | $225,943 | $103,400 |
$196,143
2,482,869
kWh
|
$29,800
-
MMBtu
|
||
TOTAL IMPLEMENTED | $145,965 | $43,600 |
$116,165
1,470,482
kWh
|
$29,800
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs