| Assessment Year | 2012 |
|---|---|
| Principal Product | capital equipment fo the corrugated box industry |
| NAICS | 333243: Sawmill, Woodworking, and Paper Machinery Manufacturing |
| SIC | 3554: Paper Industries Machinery |
| Sales Range | $50 M to 100M |
| # of Employees | 300 |
| Plant Area |
200,000
ft2
|
| Annual Production | 9,999,999,999
units
|
| Production Hrs. Annual | 7,488
hrs
|
| Location (State) | Maryland |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $752,528 | 6,046,950 |
kWh
|
$0.12 |
| Natural Gas | $122,814 | 9,681 |
MMBtu
|
$12.69 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $161,388 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $93,515 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7262: Separate controls of air handlers from ac/ heating systems | $37,175 | $100 |
$37,175
299,800
kWh
|
- | |
| 02 | 2.7224: Reduce space conditioning during non-working hours | $7,948 | $100 | - |
$7,948
-
MMBtu
|
|
| 03 | 2.2437: Recover waste heat from equipment | $9,212 | $6,080 | - |
$9,212
-
MMBtu
|
|
| 04 | 2.7241: Install outside air damper / economizer on hvac unit | $25,500 | $21,080 |
$25,500
205,500
kWh
|
- | |
| 05 | 2.4322: Use or replace with energy efficient substitutes | $32,910 | $51,500 |
$32,910
265,430
kWh
|
- | |
| 06 | 2.2437: Recover waste heat from equipment | $7,995 | $4,850 | - |
$7,995
-
MMBtu
|
|
| 07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,020 | $2,800 |
$4,020
32,400
kWh
|
- | |
| 08 | 2.7135: Install occupancy sensors | $2,640 | $620 |
$2,640
21,340
kWh
|
- | |
| 09 | 2.2414: Use waste heat from hot flue gases to preheat | $23,794 | $80,000 | - |
$23,794
-
MMBtu
|
|
| 10 | 2.7244: Revise smoke cleanup from operations | $3,290 | $11,200 |
$3,290
26,500
kWh
|
- | |
| 11 | 2.7243: Improve air circulation with destratification fans / other methods | $5,894 | $11,040 |
$(-1,860.0)
(-15,000)
kWh
|
$7,754
-
MMBtu
|
|
| 12 | 2.6218: Turn off equipment when not in use | $1,010 | $500 |
$1,010
8,150
kWh
|
- | |
| TOTAL RECOMMENDED | $161,388 | $189,870 |
$104,685
844,120
kWh
|
$56,703
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $93,515 | $98,230 |
$68,360
551,170
kWh
|
$25,155
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs