| Assessment Year | 2011 |
|---|---|
| Principal Product | Fiberglass reinforced plastic (FRP) tanks, vessels, equipment, pipe and |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 66 |
| Plant Area |
46,000
ft2
|
| Annual Production | 475,000
lb
|
| Production Hrs. Annual | 2,742
hrs
|
| Location (State) | Maryland |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $56,421 | 451,121 |
kWh
|
$0.13 |
| LPG | $39,038 | 1,750 |
MMBtu
|
$22.31 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $57,760 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $32,040 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4131: Size electric motors for peak operating efficiency | $6,390 | $2,000 |
$6,390
51,140
kWh
|
- | |
| 02 | 2.7496: Install partitions to reduce size of conditioned space | $12,050 | $4,500 | - |
$12,050
-
MMBtu
|
|
| 03 | 2.6125: Keep equipment clean | $9,770 | $2,000 | - |
$9,770
-
MMBtu
|
|
| 04 | 2.7243: Improve air circulation with destratification fans / other methods | $3,870 | $39,300 |
$(-810.0)
(-6,490)
kWh
|
$4,680
-
MMBtu
|
|
| 05 | 2.7492: Use proper thickness of insulation on building envelope | $13,165 | $87,400 | - |
$13,165
-
MMBtu
|
|
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,380 | $17,150 |
$5,380
43,000
kWh
|
- | |
| 07 | 2.2437: Recover waste heat from equipment | $3,320 | $1,900 | - |
$3,320
-
MMBtu
|
|
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,345 | $6,300 |
$2,345
18,750
kWh
|
- | |
| 09 | 2.4231: Reduce the pressure of compressed air to the minimum required | $960 | $300 |
$960
7,700
kWh
|
- | |
| 10 | 2.4221: Install compressor air intakes in coolest locations | $510 | $1,300 |
$510
4,100
kWh
|
- | |
| TOTAL RECOMMENDED | $57,760 | $162,150 |
$14,775
118,200
kWh
|
$42,985
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $32,040 | $11,700 |
$6,900
55,240
kWh
|
$25,140
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | LPG Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs