| Assessment Year | 2010 |
|---|---|
| Principal Product | Chromatogrphs and spectrometers |
| NAICS | 339112: Surgical and Medical Instrument Manufacturing |
| SIC | 3841: Surgical and Medical Instruments and Apparatus |
| Sales Range | $100 M to 500M |
| # of Employees | 400 |
| Plant Area |
131,770
ft2
|
| Annual Production | 1
units
|
| Production Hrs. Annual | 3,120
hrs
|
| Location (State) | Delaware |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,564,256 | 13,812,707 |
kWh
|
$0.11 |
| Natural Gas | $119,599 | 8,215 |
MMBtu
|
$14.56 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $441,945 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $156,800 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7314: Reduce ventilation air | $152,300 | $500,000 |
$126,560
1,120,000
kWh
|
$25,740
-
MMBtu
|
|
| 02 | 2.7235: Install fossil fuel make-up air unit | $95,200 | $250,000 |
$217,600
1,925,000
kWh
|
$(-122,400.0)
-
MMBtu
|
|
| 03 | 2.7124: Make a practice of turning off lights when not needed | $143,000 | $4,268 |
$143,000
567,750
kWh
|
- | |
| 04 | 2.7122: Disconnect ballasts | $12,500 | $350 |
$12,500
111,000
kWh
|
- | |
| 05 | 2.6218: Turn off equipment when not in use | $11,800 | $250 |
$11,800
105,000
kWh
|
- | |
| 06 | 2.7221: Lower temperature during the winter season and vice-versa | $10,400 | $100 |
$10,400
92,000
kWh
|
- | |
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,080 | $6,300 |
$6,080
53,800
kWh
|
- | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,000 | $7,644 |
$2,000
43,350
kWh
|
- | |
| 09 | 2.4222: Install adequate dryers on air lines to eliminate blowdown | $4,200 | $10,000 |
$4,200
32,270
kWh
|
- | |
| 10 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,110 | $18,280 |
$2,110
18,600
kWh
|
- | |
| 11 | 2.4221: Install compressor air intakes in coolest locations | $1,215 | $2,500 |
$1,215
10,750
kWh
|
- | |
| 12 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,140 | $5,050 |
$1,140
10,100
kWh
|
- | |
| TOTAL RECOMMENDED | $441,945 | $804,742 |
$538,605
4,089,620
kWh
|
$(-96,660.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $156,800 | $12,162 |
$156,800
716,100
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs