Assessment Year 2009
Principal Product Newspapers
NAICS 511110: Newspaper Publishers
SIC 2711: Newspapers: Publishing, or Publishing and Printing
Sales Range less than $500
k
# of Employees 60
Plant Area 20,000
ft2
Annual Production 842,995,462
pieces
Production Hrs. Annual 8,760
hrs
Location (State) Maryland

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $207,000 1,500,000
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $55,828 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $50,629

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.6218: Turn off equipment when not in use $16,118 - $16,118
117,650
kWh
-
02 2.6218: Turn off equipment when not in use $8,206 - $8,206
59
kWh
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $22,300 $500 $22,300
162,800
kWh
-
04 2.2437: Recover waste heat from equipment $3,056 $1,430 - $3,056
-
MMBtu
05 2.4221: Install compressor air intakes in coolest locations $1,568 $620 $1,568
11,443
kWh
-
06 2.6211: Conserve energy by efficient use of vending machines $575 $680 $575
4,200
kWh
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $4,005 $500 $4,005
29,237
kWh
-
TOTAL RECOMMENDED $55,828 $3,730 $52,772
325,389
kWh
$3,056
-
MMBtu
TOTAL IMPLEMENTED $50,629 $1,000 $50,629
309,746
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs