ITAC Assessment: DL0034
ITAC logo
ITAC Assessment: DL0034
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2009
Principal Product Metal Vessels
NAICS 332312: Fabricated Structural Metal Manufacturing
SIC 3441: Fabricated Structural Metal
Sales Range $5
M
to 10
M
# of Employees 25
Plant Area 57,000
ft2
Annual Production 5,900,000
units
Production Hrs. Annual 3,234
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $57,733 352,600
kWh
Natural Gas $53,414 4,509
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $32,639 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $19,837

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7261: Install timers and/or thermostats $5,400 $3,600 - $5,400
-
MMBtu
02 2.7243: Improve air circulation with destratification fans / other methods $3,702 $5,000 $(-198.0)
(-1,200)
kWh
$3,900
-
MMBtu
03 2.7491: Insulate glazing, walls, ceilings, and roofs $3,700 $4,440 - $3,700
-
MMBtu
04 2.7142: Utilize higher efficiency lamps and/or ballasts $10,489 $55,984 $10,489
63,568
kWh
-
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $5,600 $4,000 $5,600
35,000
kWh
-
06 2.4322: Use or replace with energy efficient substitutes $2,735 $18,313 $2,735
16,850
kWh
-
07 2.6218: Turn off equipment when not in use $700 - $700
4,350
kWh
-
08 2.7131: Add area lighting switches $313 $197 $313
1,900
kWh
-
TOTAL RECOMMENDED $32,639 $91,534 $19,639
120,468
kWh
$13,000
-
MMBtu
TOTAL IMPLEMENTED $19,837 $78,494 $19,837
121,668
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs