Assessment Year | 2003 |
---|---|
Principal Product | School uniforms |
NAICS | 315210: Cut and Sew Apparel Contractors |
SIC | 2369: Girls', Children's, and Infants' Outerwear, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 140 |
Plant Area |
98,000
ft2
|
Annual Production | 500,000
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $29,068 | 572,200 |
kWh
|
$0.051 |
Electricity Demand | $15,971 | 3,266 |
kW-mo/yr
|
$4.89 |
Electricity Fees | $2,670 | - |
|
- |
LPG | $29,516 | 2,748 |
MMBtu
|
$10.74 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $4,121 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,770 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $728 | $2,803 |
$462
9,093
kWh
|
$266
-
kW-mo/yr
|
- | - | - | |
02 | 2.6218: Turn off equipment when not in use | $1,885 | $610 |
$1,885
37,100
kWh
|
- | - | - | - | |
03 | 3.5311: Recover and reuse waste material | $990 | $400 | - | - | - |
$390
-
lb
|
$600 | |
04 | 2.7134: Use photocell controls | $167 | $235 |
$132
2,606
kWh
|
$35
-
kW-mo/yr
|
- | - | - | |
05 | 2.2491: Use cooling air which cools hot work pieces for space heating | $351 | $900 | - | - |
$351
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $4,121 | $4,948 |
$2,479
48,799
kWh
|
$301
-
kW-mo/yr
|
$351
-
MMBtu
|
$390
-
lb
|
$600 | ||
TOTAL IMPLEMENTED | $3,770 | $4,048 |
$2,479
48,799
kWh
|
$301
-
kW-mo/yr
|
- |
$390
-
lb
|
$600 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs