Assessment Year | 2016 |
---|---|
Principal Product | Knives |
NAICS | 332215: Metal Kitchen Cookware, Utensil, Cutlery, and Flatware (except Precious) Manufacturing |
SIC | 3421: Cutlery |
Sales Range | $10 M to 50M |
# of Employees | 95 |
Plant Area |
57,500
ft2
|
Annual Production | 288,000
units
|
Production Hrs. Annual | 6,864
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $36,500 | 847,563 |
kWh
|
$0.043 |
Electricity Demand | $52,181 | 2,387 |
kW-mo/yr
|
$21.86 |
Electricity Fees | $898 | - |
|
- |
Natural Gas | $13,007 | 2,334 |
MMBtu
|
$5.57 |
TOTAL YEARLY COSTS | $102,586 | |||
RECOMMENDED SAVINGS* | $17,200 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,020 | $1,730 |
$540
13,600
kWh
|
$480
-
kW-mo/yr
|
- | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $450 | $750 |
$220
5,500
kWh
|
$230
-
kW-mo/yr
|
- | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,360 | $5,950 |
$2,120
41,000
kWh
|
$3,110
-
kW-mo/yr
|
$40 | - | $90 | |
04 | 2.7232: Replace existing hvac unit with high efficiency model | $4,970 | $34,800 |
$1,120
28,100
kWh
|
$3,850
-
kW-mo/yr
|
- | - | - | |
05 | 2.8121: Apply for tax-free status for energy purchases | $3,200 | $500 | - | - | - | $3,200 | - | |
06 | 2.7252: Utilize an evaporative air pre-cooler or other heat exchanger in ac system | $2,200 | $9,200 |
$420
10,500
kWh
|
$1,780
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $17,200 | $52,930 |
$4,420
98,700
kWh
|
$9,450
-
kW-mo/yr
|
$40 | $3,200 | $90 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs