Assessment Year | 2016 |
---|---|
Principal Product | MDF Doors |
NAICS | 321911: Wood Window and Door Manufacturing |
SIC | 2431: Millwork |
Sales Range | $50 M to 100M |
# of Employees | 200 |
Plant Area |
154,116
ft2
|
Annual Production | 200,000
pieces
|
Production Hrs. Annual | 6,552
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $193,761 | 4,851,104 |
kWh
|
$0.040 |
Electricity Demand | $261,230 | 13,110 |
kW-mo/yr
|
$19.93 |
Electricity Fees | $3,496 | - |
|
- |
Natural Gas | $47,946 | 7,517 |
MMBtu
|
$6.38 |
LPG | $30,261 | 831 |
MMBtu
|
$36.42 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $30,470 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $18,270 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $5,760 | $9,430 |
$2,600
69,300
kWh
|
$3,160
-
kW-mo/yr
|
- | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,510 | $23,940 |
$6,980
186,100
kWh
|
$10,690
-
kW-mo/yr
|
$40 | - | $(-2,200.0) | |
03 | 2.9114: Use solar heat to make electricty | $5,670 | $31,320 |
$4,750
45,800
kWh
|
- | - | $920 | - | |
04 | 2.8121: Apply for tax-free status for energy purchases | $2,760 | $2,500 | - | - | - | $2,760 | - | |
05 | 2.7252: Utilize an evaporative air pre-cooler or other heat exchanger in ac system | $770 | $3,450 |
$150
4,100
kWh
|
$620
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $30,470 | $70,640 |
$14,480
305,300
kWh
|
$14,470
-
kW-mo/yr
|
$40 | $3,680 | $(-2,200.0) | ||
TOTAL IMPLEMENTED | $18,270 | $26,440 |
$6,980
186,100
kWh
|
$10,690
-
kW-mo/yr
|
$40 | $2,760 | $(-2,200.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs