ITAC Assessment: CO0649
ITAC logo
ITAC Assessment: CO0649
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2011
Principal Product Wind turbine components
NAICS 335312: Motor and Generator Manufacturing
SIC 3621: Motors and Generators
Sales Range greater than $500
M
# of Employees 290
Plant Area 271,425
ft2
Annual Production 650
pieces
Production Hrs. Annual 2,090
hrs
Location (State) Colorado

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $187,315 3,291,840
kWh
Electricity Demand $168,640 9,779
kW-mo/yr
Electricity Fees $1,220 -
Natural Gas $39,043 5,691
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $70,840 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.6218: Turn off equipment when not in use $12,260 $3,200 $12,260
248,400
kWh
- -
02 2.3191: Use demand controller or load shedder $9,530 $20,000 - $9,530
-
kW-mo/yr
-
03 2.6218: Turn off equipment when not in use $2,610 $480 $2,610
52,800
kWh
- -
04 2.2711: Utilize outside air instead of conditioned air for drying $1,270 $3,910 - - $1,270
-
MMBtu
05 2.7145: Install skylights $38,050 $70,550 $21,800
441,800
kWh
$13,890
-
kW-mo/yr
$2,360
-
MMBtu
06 2.7314: Reduce ventilation air $3,200 $60 $330
6,600
kWh
$1,100
-
kW-mo/yr
$1,770
-
MMBtu
07 2.7264: Interlock heating and air conditioning systems to prevent simultaneous operation $2,770 $60 - - $2,770
-
MMBtu
08 2.7264: Interlock heating and air conditioning systems to prevent simultaneous operation $1,150 $60 $120
2,500
kWh
$610
-
kW-mo/yr
$420
-
MMBtu
TOTAL RECOMMENDED $70,840 $98,320 $37,120
752,100
kWh
$25,130
-
kW-mo/yr
$8,590
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs