Assessment Year | 2007 |
---|---|
Principal Product | Hardwood molding and millwork |
NAICS | 321918: Other Millwork (including Flooring) |
SIC | 2431: Millwork |
Sales Range | $10 M to 50M |
# of Employees | 40 |
Plant Area |
36,000
ft2
|
Annual Production | 3,500,000
thousand feet
|
Production Hrs. Annual | 2,275
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $16,838 | 537,600 |
kWh
|
$0.031 |
Electricity Demand | $41,854 | 2,830 |
kW-mo/yr
|
$14.79 |
Electricity Fees | $337 | - |
|
- |
Natural Gas | $26,133 | 33,370 |
MMBtu
|
$0.78 |
Fuel Oil #2 | $63,870 | 3,134 |
MMBtu
|
$20.38 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,040 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,830 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Fuel Oil #2 Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7442: Keep doors and windows shut when not on use | $8,830 | $10,000 | - | - |
$8,830
-
MMBtu
|
- | - | - | |
02 | 2.8226: Increase efficiency of trucks | $3,780 | - | - | - | - |
$3,780
-
MMBtu
|
- | - | |
03 | 2.7243: Improve air circulation with destratification fans / other methods | $2,590 | $10,010 |
$(-250.0)
(-8,000)
kWh
|
$(-170.0)
-
kW-mo/yr
|
$3,010
-
MMBtu
|
- | - | - | |
04 | 2.9114: Use solar heat to make electricty | $1,650 | $11,000 |
$450
14,600
kWh
|
$1,200
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $610 | $3,710 |
$170
5,600
kWh
|
$410
-
kW-mo/yr
|
- | - | $10 | $20 | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $580 | $1,710 |
$220
7,200
kWh
|
$340
-
kW-mo/yr
|
- | - | $20 | - | |
TOTAL RECOMMENDED | $18,040 | $36,430 |
$590
19,400
kWh
|
$1,780
-
kW-mo/yr
|
$11,840
-
MMBtu
|
$3,780
-
MMBtu
|
$30 | $20 | ||
TOTAL IMPLEMENTED | $8,830 | $10,000 | - | - |
$8,830
-
MMBtu
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Fuel Oil #2 Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs