Assessment Year 2006
Principal Product Breakfast cereals
NAICS 311230: Breakfast Cereal Manufacturing
SIC 2043: Cereal Breakfast Foods
Sales Range less than $500
k
# of Employees 200
Plant Area 176,100
ft2
Annual Production 13,000,000
pieces
Production Hrs. Annual 8,760
hrs
Location (State) New Mexico

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,015,524 26,820,000
kWh
Electricity Demand $493,447 50,734
kW-mo/yr
Electricity Fees $68,434 -
Natural Gas $1,494,479 149,959
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $371,480 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $81,490

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
01 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat $264,540 $1,173,000 $186,670
4,943,300
kWh
$77,870
-
kW-mo/yr
- -
02 2.2692: Use outside cold water source as a supply of cooling water $56,580 $570 $40,430
1,079,000
kWh
$16,150
-
kW-mo/yr
- -
03 2.2136: Install / repair insulation on steam lines $950 $500 - - $950
-
MMBtu
-
04 2.7233: Use properly designed and sized hvac equipment $23,960 - $17,120
456,800
kWh
$6,840
-
kW-mo/yr
- -
05 2.7252: Utilize an evaporative air pre-cooler or other heat exchanger in ac system $21,540 $100,800 $11,050
322,600
kWh
$10,490
-
kW-mo/yr
- -
06 2.9114: Use solar heat to make electricty $3,910 $32,600 $1,100
23,000
kWh
$870
-
kW-mo/yr
- $1,940
TOTAL RECOMMENDED $371,480 $1,307,470 $256,370
6,824,700
kWh
$112,220
-
kW-mo/yr
$950
-
MMBtu
$1,940
TOTAL IMPLEMENTED $81,490 $1,070 $57,550
1,535,800
kWh
$22,990
-
kW-mo/yr
$950
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs