Assessment Year 2006
Principal Product Plastic bottles
NAICS 326160: Plastics Bottle Manufacturing
SIC 3085: Plastics Bottles
Sales Range $10
M
to 50
M
# of Employees 54
Plant Area 145,000
ft2
Annual Production 400,000,000
pieces
Production Hrs. Annual 8,760
hrs
Location (State) Colorado

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $960,261 25,560,122
kWh
Electricity Demand $583,212 42,293
kW-mo/yr
Electricity Fees $1,671 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $75,554 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $74,124

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.4221: Install compressor air intakes in coolest locations $17,610 $9,470 $17,610
306,866
kWh
- - -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $9,500 $50 $6,040
186,200
kWh
$3,460
-
kW-mo/yr
- -
03 2.4133: Use most efficient type of electric motors $1,244 $493 $785
24,193
kWh
$459
-
kW-mo/yr
- -
04 2.2511: Insulate bare equipment $200 $510 $130
3,900
kWh
$70
-
kW-mo/yr
- -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $42,290 $57,670 $26,970
831,100
kWh
$13,330
-
kW-mo/yr
$620 $1,370
06 2.2711: Utilize outside air instead of conditioned air for drying $1,680 $1,310 $1,070
33,000
kWh
$610
-
kW-mo/yr
- -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $1,600 $2,970 $520
16,000
kWh
$390
-
kW-mo/yr
- $690
08 2.9114: Use solar heat to make electricty $1,300 $2,950 $460
14,100
kWh
$840
-
kW-mo/yr
- -
09 2.7135: Install occupancy sensors $130 $390 $120
3,600
kWh
$10
-
kW-mo/yr
- -
TOTAL RECOMMENDED $75,554 $75,813 $53,705
1,418,959
kWh
$19,169
-
kW-mo/yr
$620 $2,060
TOTAL IMPLEMENTED $74,124 $72,473 $53,125
1,401,259
kWh
$18,319
-
kW-mo/yr
$620 $2,060
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs