Assessment Year 2004
Principal Product Corrugated paperboard containers
NAICS 322211: Corrugated and Solid Fiber Box Manufacturing
SIC 2653: Corrugated and Solid Fiber Boxes
Sales Range $10
M
to 50
M
# of Employees 135
Plant Area 244,000
ft2
Annual Production 307,000
thousand feet
Production Hrs. Annual 4,290
hrs
Location (State) Colorado

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $81,771 2,794,876
kWh
Electricity Demand $130,857 9,803
kW-mo/yr
Electricity Fees $384 -
Natural Gas $129,574 23,667
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $15,610 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $11,210

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.4226: Use / purchase optimum sized compressor $4,990 $500 $4,380
146,300
kWh
$610
-
kW-mo/yr
- - -
02 2.4239: Eliminate or reduce compressed air usage $3,660 $700 $1,630
54,400
kWh
$2,030
-
kW-mo/yr
- - -
03 2.4231: Reduce the pressure of compressed air to the minimum required $2,070 $60 $920
30,600
kWh
$1,150
-
kW-mo/yr
- - -
04 2.2511: Insulate bare equipment $780 $1,640 - - $780
-
MMBtu
- -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $710 $70 $320
10,600
kWh
$390
-
kW-mo/yr
- - -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $2,660 $9,120 $1,380
46,100
kWh
$1,720
-
kW-mo/yr
- - $(-440.0)
07 2.7134: Use photocell controls $740 $3,340 $300
10,000
kWh
$370
-
kW-mo/yr
- $30 $40
TOTAL RECOMMENDED $15,610 $15,430 $8,930
298,000
kWh
$6,270
-
kW-mo/yr
$780
-
MMBtu
$30 $(-400.0)
TOTAL IMPLEMENTED $11,210 $11,390 $7,000
233,600
kWh
$3,870
-
kW-mo/yr
$780
-
MMBtu
- $(-440.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs