Assessment Year | 2002 |
---|---|
Principal Product | Machined silicon parts |
NAICS |
n/a
|
SIC | 3674: Semiconductors and Related Devices |
Sales Range | $5 M to 10M |
# of Employees | 35 |
Plant Area |
19,600
ft2
|
Annual Production | 282,000
pieces
|
Production Hrs. Annual | 5,200
hrs
|
Location (State) | Montana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $19,352 | 546,320 |
kWh
|
$0.035 |
Electricity Demand | $22,721 | 2,829 |
kW-mo/yr
|
$8.03 |
Electricity Fees | $96 | - |
|
- |
Natural Gas | $3,102 | 498 |
MMBtu
|
$6.23 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $20,613 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $273 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $273 | $456 |
$196
4,849
kWh
|
$77
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.3191: Use demand controller or load shedder | $1,160 | $2,000 | - |
$1,160
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.7135: Install occupancy sensors | $510 | $770 |
$410
10,200
kWh
|
$100
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.4226: Use / purchase optimum sized compressor | $200 | - |
$200
5,000
kWh
|
- | - | - | - | - | |
05 | 3.3122: Use filtration, centrifuging to remove contaminants | $18,470 | $30,800 | - | - |
$7,090
-
Tgal
|
$(-5,850.0) | $14,270 |
$2,960
-
Tgal
|
|
TOTAL RECOMMENDED | $20,613 | $34,026 |
$806
20,049
kWh
|
$1,337
-
kW-mo/yr
|
$7,090
-
Tgal
|
$(-5,850.0) | $14,270 |
$2,960
-
Tgal
|
||
TOTAL IMPLEMENTED | $273 | $456 |
$196
4,849
kWh
|
$77
-
kW-mo/yr
|
- | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs