Assessment Year | 1999 |
---|---|
Principal Product | plexiglass skylights & parts |
NAICS |
n/a
|
SIC | 3038: |
Sales Range | $10 M to 50M |
# of Employees | 52 |
Plant Area |
77,000
ft2
|
Annual Production | 2,440
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $17,815 | 973,623 |
kWh
|
$0.018 |
Electricity Demand | $52,197 | 3,742 |
kW-mo/yr
|
$13.95 |
Electricity Fees | $204 | - |
|
- |
Natural Gas | $6,426 | 1,447 |
MMBtu
|
$4.44 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $384,582 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,980 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Solid Waste (haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Primary Product Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,620 | $330 |
$820
45,135
kWh
|
$1,800
-
kW-mo/yr
|
- | - | - | - | - | - | - | |
02 | 2.3191: Use demand controller or load shedder | $2,490 | $4,000 | - |
$2,490
-
kW-mo/yr
|
- | - | - | - | - | - | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $360 | $50 |
$110
6,155
kWh
|
$250
-
kW-mo/yr
|
- | - | - | - | - | - | - | |
04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $240 | $450 | - | - |
$240
-
MMBtu
|
- | - | - | - | - | - | |
05 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $1,720 | - | - | - | - |
$1,720
-
lb
|
- | - | - | - | - | |
06 | 3.6192: Use a less expensive method of waste removal | $1,352 | - | - | - | - | - |
$1,520
-
lb
|
- | $(-168.0) | - | - | |
07 | 4.111: Add equipment/ operators to reduce production bottleneck | $318,400 | $105,000 | - | - | - | - | - | $(-41,600.0) | - | - | $360,000 | |
08 | 4.122: Develop standard procedures to improve internal yields | $57,400 | $10,000 | - | - | - | - | - | - | - | $57,400 | - | |
TOTAL RECOMMENDED | $384,582 | $119,830 |
$930
51,290
kWh
|
$4,540
-
kW-mo/yr
|
$240
-
MMBtu
|
$1,720
-
lb
|
$1,520
-
lb
|
$(-41,600.0) | $(-168.0) | $57,400 | $360,000 | ||
TOTAL IMPLEMENTED | $2,980 | $380 |
$930
51,290
kWh
|
$2,050
-
kW-mo/yr
|
- | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Solid Waste (haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Primary Product Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs