Assessment Year | 1997 |
---|---|
Principal Product | musical support equipment |
NAICS |
n/a
|
SIC | 3931: Musical Instruments |
Sales Range | $10 M to 50M |
# of Employees | 80 |
Plant Area |
56,000
ft2
|
Annual Production | 51,300
pieces
|
Production Hrs. Annual | 2,265
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $7,592 | 378,664 |
kWh
|
$0.020 |
Electricity Demand | $17,856 | 1,376 |
kW-mo/yr
|
$12.98 |
Electricity Fees | $369 | - |
|
- |
Natural Gas | $8,712 | 2,432 |
MMBtu
|
$3.58 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $16,861 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,861 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7224: Reduce space conditioning during non-working hours | $3,020 | $1,690 |
$260
15,826
kWh
|
- |
$2,760
-
MMBtu
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $691 | $1,050 |
$159
9,672
kWh
|
$532
-
kW-mo/yr
|
- | - | |
03 | 2.7135: Install occupancy sensors | $270 | $1,000 |
$30
1,758
kWh
|
$60
-
kW-mo/yr
|
$180
-
MMBtu
|
- | |
04 | 2.4321: Upgrade obsolete equipment | $180 | $540 |
$70
4,103
kWh
|
$110
-
kW-mo/yr
|
- | - | |
05 | 2.6218: Turn off equipment when not in use | $100 | - |
$100
6,155
kWh
|
- | - | - | |
06 | 4.442: Install magazines for temporary storage | $12,600 | $3,600 | - | - | - | $12,600 | |
TOTAL RECOMMENDED | $16,861 | $7,880 |
$619
37,514
kWh
|
$702
-
kW-mo/yr
|
$2,940
-
MMBtu
|
$12,600 | ||
TOTAL IMPLEMENTED | $16,861 | $7,880 |
$619
37,514
kWh
|
$702
-
kW-mo/yr
|
$2,940
-
MMBtu
|
$12,600 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs