| Assessment Year | 1997 |
|---|---|
| Principal Product | automotive ic sensors |
| NAICS |
n/a
|
| SIC | 3679: Electronic Components, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 240 |
| Plant Area |
111,000
ft2
|
| Annual Production | 6,600
pieces
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $324,797 | 11,693,728 |
kWh
|
$0.028 |
| Electricity Demand | $145,714 | 19,480 |
kW-mo/yr
|
$7.48 |
| Electricity Fees | $14,520 | - |
|
- |
| Natural Gas | $100,212 | 25,892 |
MMBtu
|
$3.87 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $1,985,777 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $9,887 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (haz) Savings | Water Consumption Savings | Increase in Production Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,660 | $28,150 |
$4,910
174,091
kWh
|
$2,750
-
kW-mo/yr
|
- | - | - | - | - | |
| 02 | 2.4133: Use most efficient type of electric motors | $557 | $980 |
$409
14,361
kWh
|
$148
-
kW-mo/yr
|
- | - | - | - | - | |
| 03 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $3,770 | $5,700 | - | - |
$3,770
-
MMBtu
|
- | - | - | - | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $350 | $590 |
$260
9,086
kWh
|
$90
-
kW-mo/yr
|
- | - | - | - | - | |
| 05 | 3.4115: Recover and reuse cooling water | $1,320 | $1,580 | - | - | - |
$340
-
Tgal
|
- |
$980
-
Tgal
|
- | |
| 06 | 3.6192: Use a less expensive method of waste removal | $1,120 | $160 | - | - | - | - |
$1,120
-
lb
|
- | - | |
| 07 | 4.122: Develop standard procedures to improve internal yields | $1,971,000 | $100,000 | - | - | - | - | - | - | $1,971,000 | |
| TOTAL RECOMMENDED | $1,985,777 | $137,160 |
$5,579
197,538
kWh
|
$2,988
-
kW-mo/yr
|
$3,770
-
MMBtu
|
$340
-
Tgal
|
$1,120
-
lb
|
$980
-
Tgal
|
$1,971,000 | ||
| TOTAL IMPLEMENTED | $9,887 | $31,300 |
$5,579
197,538
kWh
|
$2,988
-
kW-mo/yr
|
- |
$340
-
Tgal
|
- |
$980
-
Tgal
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (haz) Savings | Water Consumption Savings | Increase in Production Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs