Assessment Year | 1996 |
---|---|
Principal Product | skis and snowboards |
NAICS |
n/a
|
SIC | 3949: Sporting and Athletic Goods, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 160 |
Plant Area |
55,000
ft2
|
Annual Production | 50,000
pieces
|
Production Hrs. Annual | 5,064
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $45,893 | 1,518,464 |
kWh
|
$0.030 |
Electricity Demand | $50,357 | 4,293 |
kW-mo/yr
|
$11.73 |
Electricity Fees | $299 | - |
|
- |
Natural Gas | $20,588 | 5,485 |
MMBtu
|
$3.75 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $106,763 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $103,453 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Product Savings | By-product Production Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 4.652: Replace existing equipment with more suitable substitutes | $37,440 | $48,250 | - | - | - | - | - | $37,440 | - | |
02 | 4.124: Install continuous lubrication equipment | $32,640 | $3,000 | - | - | - | - | - | $32,640 | - | |
03 | 4.514: Re-arrange equipment layout to reduce handling costs | $29,180 | $270 | - | - | - | - | - | $29,180 | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,307 | $5,236 |
$533
17,585
kWh
|
$774
-
kW-mo/yr
|
- | - | - | - | - | |
05 | 2.8121: Apply for tax-free status for energy purchases | $2,260 | $400 | - | - | - | - | $2,260 | - | - | |
06 | 2.7224: Reduce space conditioning during non-working hours | $1,810 | $1,560 |
$20
586
kWh
|
- |
$1,790
-
MMBtu
|
- | - | - | - | |
07 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $1,500 | $8,000 | - | - | - | $(-170.0) | - | - | $1,670 | |
08 | 2.4221: Install compressor air intakes in coolest locations | $580 | $400 |
$300
9,965
kWh
|
$280
-
kW-mo/yr
|
- | - | - | - | - | |
09 | 2.4133: Use most efficient type of electric motors | $46 | $25 |
$24
879
kWh
|
$22
-
kW-mo/yr
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $106,763 | $67,141 |
$877
29,015
kWh
|
$1,076
-
kW-mo/yr
|
$1,790
-
MMBtu
|
$(-170.0) | $2,260 | $99,260 | $1,670 | ||
TOTAL IMPLEMENTED | $103,453 | $57,581 |
$857
28,429
kWh
|
$1,076
-
kW-mo/yr
|
- | - | $2,260 | $99,260 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Product Savings | By-product Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs