Assessment Year | 1996 |
---|---|
Principal Product | large diameter welded steel pipe |
NAICS |
n/a
|
SIC | 3317: Steel Pipe and Tubes |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
133,900
ft2
|
Annual Production | 26,000
ton
|
Production Hrs. Annual | 5,200
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $79,679 | 3,744,431 |
kWh
|
$0.021 |
Electricity Demand | $155,007 | 12,149 |
kW-mo/yr
|
$12.76 |
Electricity Fees | $9,057 | - |
|
- |
Natural Gas | $89,456 | 52,178 |
MMBtu
|
$1.71 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,365 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,908 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $8,040 | $1,000 | - |
$8,040
-
kW-mo/yr
|
- | |
02 | 3.5313: Increase amount of waste recovered for resale | $7,040 | - | - | - |
$7,040
-
lb
|
|
03 | 2.4133: Use most efficient type of electric motors | $518 | $470 |
$115
5,569
kWh
|
$403
-
kW-mo/yr
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $417 | $1,818 |
$98
4,689
kWh
|
$319
-
kW-mo/yr
|
- | |
05 | 2.4221: Install compressor air intakes in coolest locations | $1,380 | $500 |
$580
27,257
kWh
|
$800
-
kW-mo/yr
|
- | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,320 | $350 |
$560
26,084
kWh
|
$760
-
kW-mo/yr
|
- | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $650 | $2,620 |
$80
3,810
kWh
|
$570
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $19,365 | $6,758 |
$1,433
67,409
kWh
|
$10,892
-
kW-mo/yr
|
$7,040
-
lb
|
||
TOTAL IMPLEMENTED | $10,908 | $3,940 |
$1,335
62,720
kWh
|
$2,533
-
kW-mo/yr
|
$7,040
-
lb
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs