Assessment Year | 1996 |
---|---|
Principal Product | center pivot irrigation equip., planters |
NAICS |
n/a
|
SIC | 3523: Farm Machinery and Equipment |
Sales Range | $100 M to 500M |
# of Employees | 250 |
Plant Area |
144,000
ft2
|
Annual Production | 4,800
pieces
|
Production Hrs. Annual | 8,112
hrs
|
Location (State) | Nebraska |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $162,277 | 7,002,052 |
kWh
|
$0.023 |
Electricity Demand | $94,091 | 12,463 |
kW-mo/yr
|
$7.55 |
Electricity Fees | $4,320 | - |
|
- |
Natural Gas | $161,616 | 63,338 |
MMBtu
|
$2.55 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $55,828 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $40,488 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7231: Use radiant heater for spot heating | $35,150 | $17,480 |
$48,180
1,347,890
kWh
|
- |
$(-13,030.0)
-
MMBtu
|
- | - | - | |
02 | 2.4239: Eliminate or reduce compressed air usage | $3,810 | $27,530 |
$2,590
109,027
kWh
|
$1,220
-
kW-mo/yr
|
- | - | - | - | |
03 | 3.8125: Remove rollers from the machines and clean in a closed solvent cleaner | $10,070 | $1,000 | - | - | - |
$1,600
-
gal
|
$2,500 | $5,970 | |
04 | 2.4221: Install compressor air intakes in coolest locations | $2,790 | $820 |
$1,750
75,615
kWh
|
$1,040
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,460 | $4,294 |
$848
36,635
kWh
|
$612
-
kW-mo/yr
|
- | - | - | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,610 | $720 |
$1,040
44,842
kWh
|
$570
-
kW-mo/yr
|
- | - | - | - | |
07 | 2.4133: Use most efficient type of electric motors | $258 | $448 |
$161
7,034
kWh
|
$97
-
kW-mo/yr
|
- | - | - | - | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $680 | $1,480 |
$400
17,292
kWh
|
$280
-
kW-mo/yr
|
- | - | - | - | |
TOTAL RECOMMENDED | $55,828 | $53,772 |
$54,969
1,638,335
kWh
|
$3,819
-
kW-mo/yr
|
$(-13,030.0)
-
MMBtu
|
$1,600
-
gal
|
$2,500 | $5,970 | ||
TOTAL IMPLEMENTED | $40,488 | $20,948 |
$51,531
1,492,673
kWh
|
$1,987
-
kW-mo/yr
|
$(-13,030.0)
-
MMBtu
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs