Assessment Year 1996
Principal Product center pivot irrigation equip., planters
NAICS
n/a
SIC 3523: Farm Machinery and Equipment
Sales Range $100
M
to 500
M
# of Employees 250
Plant Area 144,000
ft2
Annual Production 4,800
pieces
Production Hrs. Annual 8,112
hrs
Location (State) Nebraska

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $162,277 7,002,052
kWh
Electricity Demand $94,091 12,463
kW-mo/yr
Electricity Fees $4,320 -
Natural Gas $161,616 63,338
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $55,828 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $40,488

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Liquid (haz) Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.7231: Use radiant heater for spot heating $35,150 $17,480 $48,180
1,347,890
kWh
- $(-13,030.0)
-
MMBtu
- - -
02 2.4239: Eliminate or reduce compressed air usage $3,810 $27,530 $2,590
109,027
kWh
$1,220
-
kW-mo/yr
- - - -
03 3.8125: Remove rollers from the machines and clean in a closed solvent cleaner $10,070 $1,000 - - - $1,600
-
gal
$2,500 $5,970
04 2.4221: Install compressor air intakes in coolest locations $2,790 $820 $1,750
75,615
kWh
$1,040
-
kW-mo/yr
- - - -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $1,460 $4,294 $848
36,635
kWh
$612
-
kW-mo/yr
- - - -
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,610 $720 $1,040
44,842
kWh
$570
-
kW-mo/yr
- - - -
07 2.4133: Use most efficient type of electric motors $258 $448 $161
7,034
kWh
$97
-
kW-mo/yr
- - - -
08 2.4111: Utilize energy-efficient belts and other improved mechanisms $680 $1,480 $400
17,292
kWh
$280
-
kW-mo/yr
- - - -
TOTAL RECOMMENDED $55,828 $53,772 $54,969
1,638,335
kWh
$3,819
-
kW-mo/yr
$(-13,030.0)
-
MMBtu
$1,600
-
gal
$2,500 $5,970
TOTAL IMPLEMENTED $40,488 $20,948 $51,531
1,492,673
kWh
$1,987
-
kW-mo/yr
$(-13,030.0)
-
MMBtu
- - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Liquid (haz) Savings Personnel Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs