Assessment Year | 1996 |
---|---|
Principal Product | food service equipment |
NAICS |
n/a
|
SIC | 3589: Service Industry Machinery, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 230 |
Plant Area |
210,000
ft2
|
Annual Production | 4,000,000
lb
|
Production Hrs. Annual | 4,250
hrs
|
Location (State) | Wyoming |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $50,696 | 2,341,442 |
kWh
|
$0.022 |
Electricity Demand | $55,251 | 6,268 |
kW-mo/yr
|
$8.81 |
Electricity Fees | $677 | - |
|
- |
Natural Gas | $48,288 | 13,744 |
MMBtu
|
$3.51 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $43,520 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $18,220 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Solid Waste (haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $12,310 | $8,000 | - | - | - | - |
$12,310
-
lb
|
- | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,050 | $21,648 |
$3,068
141,559
kWh
|
$3,982
-
kW-mo/yr
|
- | - | - | - | - | - | |
03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $9,340 | $10,650 |
$3,400
156,800
kWh
|
$8,290
-
kW-mo/yr
|
$(-2,350.0)
-
MMBtu
|
- | - | - | - | - | |
04 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $4,480 | $1,000 | - | - | - | - | - |
$1,710
-
lb
|
- | $2,770 | |
05 | 2.4322: Use or replace with energy efficient substitutes | $3,060 | $33,280 |
$930
42,790
kWh
|
$2,130
-
kW-mo/yr
|
- | - | - | - | - | - | |
06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,750 | $1,800 | - | - |
$2,750
-
MMBtu
|
- | - | - | - | - | |
07 | 2.4239: Eliminate or reduce compressed air usage | $1,540 | $8,500 |
$800
36,928
kWh
|
$740
-
kW-mo/yr
|
- | - | - | - | - | - | |
08 | 3.8125: Remove rollers from the machines and clean in a closed solvent cleaner | $1,340 | $1,000 | - | - | - |
$680
-
gal
|
- | - | $330 | $330 | |
09 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,220 | $1,500 | - | - |
$1,220
-
MMBtu
|
- | - | - | - | - | |
10 | 3.8132: Use less toxic and volatile solvent substitutes | $220 | $1,170 | - | - | - |
$600
-
gal
|
- | - | - | $(-380.0) | |
11 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $210 | $300 |
$100
4,396
kWh
|
$110
-
kW-mo/yr
|
- | - | - | - | - | - | |
TOTAL RECOMMENDED | $43,520 | $88,848 |
$8,298
382,473
kWh
|
$15,252
-
kW-mo/yr
|
$1,620
-
MMBtu
|
$1,280
-
gal
|
$12,310
-
lb
|
$1,710
-
lb
|
$330 | $2,720 | ||
TOTAL IMPLEMENTED | $18,220 | $10,800 |
$100
4,396
kWh
|
$110
-
kW-mo/yr
|
$1,220
-
MMBtu
|
- |
$12,310
-
lb
|
$1,710
-
lb
|
- | $2,770 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Solid Waste (haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs