Assessment Year 1996
Principal Product window coverings
NAICS
n/a
SIC 2591: Drapery Hardware and Window Blinds and Shades
Sales Range $50
M
to 100
M
# of Employees 365
Plant Area 113,830
ft2
Annual Production 1,011,000
pieces
Production Hrs. Annual 6,739
hrs
Location (State) Colorado

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $55,399 1,793,376
kWh
Electricity Demand $39,831 3,971
kW-mo/yr
Electricity Fees $131 -
Natural Gas $13,340 3,011
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $15,745 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $6,511

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Liquid (haz) Savings Ancillary Material Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $6,204 $14,055 $3,690
119,578
kWh
$2,514
-
kW-mo/yr
- - -
02 4.211: Consider use / purchase of bulk materials where possible $5,380 $770 $(-130.0)
(-4,103)
kWh
- - $(-300.0)
-
gal
$5,810
03 2.2437: Recover waste heat from equipment $2,230 $1,500 - - $2,230
-
MMBtu
- -
04 2.7111: Reduce illumination to minimum necessary levels $800 $430 $260
8,499
kWh
$540
-
kW-mo/yr
- - -
05 2.4221: Install compressor air intakes in coolest locations $740 $420 $470
15,240
kWh
$270
-
kW-mo/yr
- - -
06 2.4133: Use most efficient type of electric motors $61 $23 $44
1,465
kWh
$17
-
kW-mo/yr
- - -
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $330 $840 $240
7,620
kWh
$90
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $15,745 $18,038 $4,574
148,299
kWh
$3,431
-
kW-mo/yr
$2,230
-
MMBtu
$(-300.0)
-
gal
$5,810
TOTAL IMPLEMENTED $6,511 $2,053 $624
20,222
kWh
$377
-
kW-mo/yr
- $(-300.0)
-
gal
$5,810
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Liquid (haz) Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs