Assessment Year | 1995 |
---|---|
Principal Product | Rotation molded plastic parts |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 45 |
Plant Area |
45,000
ft2
|
Annual Production | 1,800,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $42,406 | 779,308 |
kWh
|
$0.054 |
Natural Gas | $54,055 | 13,674 |
MMBtu
|
$3.95 |
LPG | $1,632 | 104 |
MMBtu
|
$15.69 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,265 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,970 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | LPG Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,400 | $8,810 |
$2,400
45,428
kWh
|
- | - | |
02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $1,870 | - |
$1,870
-
kWh
|
- | - | |
03 | 2.4221: Install compressor air intakes in coolest locations | $1,260 | $400 |
$1,260
26,964
kWh
|
- | - | |
04 | 2.1332: Convert combustion equipment to burn natural gas | $1,425 | $3,020 | - |
$(-207.0)
-
MMBtu
|
$1,632
-
MMBtu
|
|
05 | 2.4131: Size electric motors for peak operating efficiency | $310 | $1,745 |
$310
5,862
kWh
|
- | - | |
TOTAL RECOMMENDED | $7,265 | $13,975 |
$5,840
78,254
kWh
|
$(-207.0)
-
MMBtu
|
$1,632
-
MMBtu
|
||
TOTAL IMPLEMENTED | $3,970 | $10,955 |
$3,970
78,254
kWh
|
- | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs