| Assessment Year | 1995 |
|---|---|
| Principal Product | Rotation molded plastic parts |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 45 |
| Plant Area |
45,000
ft2
|
| Annual Production | 1,800,000
lb
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $42,406 | 779,308 |
kWh
|
$0.054 |
| Natural Gas | $54,055 | 13,674 |
MMBtu
|
$3.95 |
| LPG | $1,632 | 104 |
MMBtu
|
$15.69 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,265 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,970 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | LPG Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,400 | $8,810 |
$2,400
45,428
kWh
|
- | - | |
| 02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $1,870 | - |
$1,870
-
kWh
|
- | - | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $1,260 | $400 |
$1,260
26,964
kWh
|
- | - | |
| 04 | 2.1332: Convert combustion equipment to burn natural gas | $1,425 | $3,020 | - |
$(-207.0)
-
MMBtu
|
$1,632
-
MMBtu
|
|
| 05 | 2.4131: Size electric motors for peak operating efficiency | $310 | $1,745 |
$310
5,862
kWh
|
- | - | |
| TOTAL RECOMMENDED | $7,265 | $13,975 |
$5,840
78,254
kWh
|
$(-207.0)
-
MMBtu
|
$1,632
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $3,970 | $10,955 |
$3,970
78,254
kWh
|
- | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs