Assessment Year | 1995 |
---|---|
Principal Product | Envelopes |
NAICS |
n/a
|
SIC | 2677: Envelopes |
Sales Range | $10 M to 50M |
# of Employees | 94 |
Plant Area |
40,000
ft2
|
Annual Production | 850,000,000
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $86,574 | 1,641,266 |
kWh
|
$0.053 |
Natural Gas | $18,409 | 4,073 |
MMBtu
|
$4.52 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $12,380 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,190 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,190 | $11,090 |
$4,190
82,943
kWh
|
- | |
02 | 2.6218: Turn off equipment when not in use | $3,360 | $320 | - |
$3,360
-
MMBtu
|
|
03 | 2.4133: Use most efficient type of electric motors | $1,870 | $640 |
$1,870
39,566
kWh
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,230 | $1,110 |
$1,230
26,671
kWh
|
- | |
05 | 2.4221: Install compressor air intakes in coolest locations | $1,110 | $400 |
$1,110
24,326
kWh
|
- | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $620 | $50 |
$620
12,016
kWh
|
- | |
TOTAL RECOMMENDED | $12,380 | $13,610 |
$9,020
185,522
kWh
|
$3,360
-
MMBtu
|
||
TOTAL IMPLEMENTED | $8,190 | $2,520 |
$4,830
102,579
kWh
|
$3,360
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs