| Assessment Year | 1995 |
|---|---|
| Principal Product | Frozen Onions |
| NAICS |
n/a
|
| SIC | 2037: Frozen Fruits, Fruit Juices, and Vegetables |
| Sales Range | $10 M to 50M |
| # of Employees | 125 |
| Plant Area |
60,000
ft2
|
| Annual Production | 26,000,000
lb
|
| Production Hrs. Annual | 8,320
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $178,659 | 4,032,239 |
kWh
|
$0.044 |
| Natural Gas | $43,628 | 11,047 |
MMBtu
|
$3.95 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $16,460 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2437: Recover waste heat from equipment | $4,670 | $16,140 |
$(-110.0)
(-2,345)
kWh
|
$4,780
-
MMBtu
|
|
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,340 | $4,890 |
$4,340
102,579
kWh
|
- | |
| 03 | 2.4133: Use most efficient type of electric motors | $4,370 | $5,280 |
$4,370
99,648
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,640 | $9,910 |
$2,640
59,789
kWh
|
- | |
| 05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $440 | $1,880 |
$(-30.0)
(-586)
kWh
|
$470
-
MMBtu
|
|
| TOTAL RECOMMENDED | $16,460 | $38,100 |
$11,210
259,085
kWh
|
$5,250
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs