Assessment Year 1995
Principal Product Plastic Bags
NAICS
n/a
SIC 2673: Plastics, Foil, and Coated Paper Bags
Sales Range $5
M
to 10
M
# of Employees 57
Plant Area 100,000
ft2
Annual Production 9,500,000
lb
Production Hrs. Annual 8,640
hrs
Location (State) Colorado

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $194,932 4,518,757
kWh
Natural Gas $10,349 2,602
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $32,520 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $4,060

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7252: Utilize an evaporative air pre-cooler or other heat exchanger in ac system $10,040 $32,850 $10,040
267,292
kWh
-
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $11,280 $12,700 $22,990
603,458
kWh
$(-11,710.0)
-
MMBtu
03 2.7231: Use radiant heater for spot heating $3,470 $5,400 - $3,470
-
MMBtu
04 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $3,150 $6,720 $3,150
80,305
kWh
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $2,470 $1,600 $2,470
62,427
kWh
-
06 2.4133: Use most efficient type of electric motors $1,590 $1,940 $1,590
40,739
kWh
-
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $520 $1,770 $520
13,482
kWh
-
TOTAL RECOMMENDED $32,520 $62,980 $40,760
1,067,703
kWh
$(-8,240.0)
-
MMBtu
TOTAL IMPLEMENTED $4,060 $3,540 $4,060
103,166
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings