| Assessment Year | 1993 |
|---|---|
| Principal Product | Cast Metal Products |
| NAICS |
n/a
|
| SIC | 3325: Steel Foundries, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 30 |
| Plant Area |
14,000
ft2
|
| Annual Production | 1,000
ton
|
| Production Hrs. Annual | 3,120
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $129,914 | 1,661,196 |
kWh
|
$0.078 |
| Natural Gas | $9,049 | 2,407 |
MMBtu
|
$3.76 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $6,360 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $870 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4221: Install compressor air intakes in coolest locations | $380 | $130 |
$380
4,982
kWh
|
|
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $490 | $300 |
$490
6,155
kWh
|
|
| 03 | 2.4226: Use / purchase optimum sized compressor | $2,070 | $5,000 |
$2,070
77,960
kWh
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $690 | $660 |
$690
8,792
kWh
|
|
| 05 | 2.4133: Use most efficient type of electric motors | $2,730 | $3,610 |
$2,730
34,877
kWh
|
|
| TOTAL RECOMMENDED | $6,360 | $9,700 |
$6,360
132,766
kWh
|
||
| TOTAL IMPLEMENTED | $870 | $430 |
$870
11,137
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs