Assessment Year | 1993 |
---|---|
Principal Product | Electronics |
NAICS |
n/a
|
SIC | 3629: Electrical Industrial Apparatus, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 105 |
Plant Area |
43,000
ft2
|
Annual Production | 4,500
pieces
|
Production Hrs. Annual | 3,250
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $56,073 | 847,304 |
kWh
|
$0.066 |
Natural Gas | $8,433 | 2,310 |
MMBtu
|
$3.65 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,730 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,970 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,900 | $250 |
$1,900
28,722
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,980 | $1,730 |
$2,980
44,842
kWh
|
- | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $1,630 | $600 |
$1,630
24,619
kWh
|
- | |
04 | 2.7314: Reduce ventilation air | $1,070 | $1,760 |
$170
2,638
kWh
|
$900
-
MMBtu
|
|
05 | 2.7261: Install timers and/or thermostats | $700 | $1,050 |
$130
4,982
kWh
|
$570
-
MMBtu
|
|
06 | 2.7135: Install occupancy sensors | $450 | $800 |
$360
5,569
kWh
|
$90
-
MMBtu
|
|
TOTAL RECOMMENDED | $8,730 | $6,190 |
$7,170
111,372
kWh
|
$1,560
-
MMBtu
|
||
TOTAL IMPLEMENTED | $2,970 | $2,010 |
$2,070
31,360
kWh
|
$900
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs