Assessment Year | 1992 |
---|---|
Principal Product | Kitchen and Bathroom Cabinets |
NAICS |
n/a
|
SIC | 3955: Carbon Paper and Inked Ribbons |
Sales Range | $10 M to 50M |
# of Employees | 120 |
Plant Area |
160,000
ft2
|
Annual Production | 150,000
pieces
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $113,293 | 1,477,140 |
kWh
|
$0.077 |
Natural Gas | $38,488 | 9,971 |
MMBtu
|
$3.86 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,420 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $18,420 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,230 | $400 |
$1,230
16,120
kWh
|
- | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,180 | $500 |
$1,180
15,240
kWh
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $1,090 | $500 |
$1,090
14,068
kWh
|
- | |
04 | 2.7224: Reduce space conditioning during non-working hours | $4,550 | $1,200 |
$320
12,309
kWh
|
$4,230
-
MMBtu
|
|
05 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $2,060 | $600 |
$2,060
26,964
kWh
|
- | |
06 | 2.4133: Use most efficient type of electric motors | $2,540 | $4,890 |
$2,540
33,118
kWh
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $350 | $750 |
$350
4,689
kWh
|
- | |
08 | 2.4133: Use most efficient type of electric motors | $1,970 | $5,240 |
$1,970
25,791
kWh
|
- | |
09 | 2.4239: Eliminate or reduce compressed air usage | $2,310 | $8,200 |
$2,310
30,188
kWh
|
- | |
10 | 2.2427: Use waste heat from hot flue gases to preheat incoming fluids | $1,140 | $4,800 | - |
$1,140
-
MMBtu
|
|
TOTAL RECOMMENDED | $18,420 | $27,080 |
$13,050
178,487
kWh
|
$5,370
-
MMBtu
|
||
TOTAL IMPLEMENTED | $18,420 | $27,080 |
$13,050
178,487
kWh
|
$5,370
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs