Assessment Year 1992
Principal Product Powdered Metals
NAICS
n/a
SIC 2819: Industrial Inorganic Chemicals, Not Elsewhere Classified
Sales Range $1
M
to 5
M
# of Employees 9
Plant Area 10,000
ft2
Annual Production 50,000
lb
Production Hrs. Annual 7,488
hrs
Location (State) Colorado

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $43,389 664,713
kWh
Natural Gas $1,682 370
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $19,834 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $19,604

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Water Disposal Savings
01 2.8121: Apply for tax-free status for energy purchases $2,430 $250 $2,356
-
kWh
$74
-
MMBtu
-
02 2.2691: Shut off cooling if cold outside air will cool process $150 $2,850 $150
2,345
kWh
- -
03 2.2511: Insulate bare equipment $3,410 $3,200 $3,410
52,169
kWh
- -
04 2.1311: Replace electrically-operated equipment with fossil fuel equipment $10,064 $12,670 $14,322
219,519
kWh
$(-4,258.0)
-
MMBtu
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $460 $530 $460
7,034
kWh
- -
06 2.4133: Use most efficient type of electric motors $290 $350 $290
4,396
kWh
- -
07 2.3137: Use power during off-peak periods $920 $1,500 $920
-
kWh
- -
08 2.2121: Increase amount of condensate returned $1,880 $5,000 $1,450
22,274
kWh
- $430
-
Tgal
09 2.7442: Keep doors and windows shut when not on use $230 $650 - $230
-
MMBtu
-
TOTAL RECOMMENDED $19,834 $27,000 $23,358
307,737
kWh
$(-3,954.0)
-
MMBtu
$430
-
Tgal
TOTAL IMPLEMENTED $19,604 $26,350 $23,358
307,737
kWh
$(-4,184.0)
-
MMBtu
$430
-
Tgal
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Water Disposal Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs