Assessment Year | 1990 |
---|---|
Principal Product | SKI LIFT SYSTEMS |
NAICS |
n/a
|
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 90 |
Plant Area |
n/a
|
Annual Production | 15
pieces
|
Production Hrs. Annual | 0
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $37,054 | 507,034 |
kWh
|
$0.073 |
Natural Gas | $6,035 | 1,175 |
MMBtu
|
$5.14 |
Other Energy | $6,724 | 98 |
MMBtu
|
$68.61 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,802 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,982 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Other Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.1332: Convert combustion equipment to burn natural gas | $6,200 | $5,400 | - |
$(-500.0)
-
MMBtu
|
$6,700
-
MMBtu
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $850 | $100 |
$850
11,723
kWh
|
- | - | |
03 | 2.4133: Use most efficient type of electric motors | $218 | $433 |
$218
2,931
kWh
|
- | - | |
04 | 2.7243: Improve air circulation with destratification fans / other methods | $1,500 | $2,000 |
$(-30.0)
(-293)
kWh
|
$1,530
-
MMBtu
|
- | |
05 | 2.4221: Install compressor air intakes in coolest locations | $1,330 | $900 |
$1,330
18,171
kWh
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $317 | $237 |
$317
4,396
kWh
|
- | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $620 | $1,460 |
$620
8,499
kWh
|
- | - | |
08 | 2.8121: Apply for tax-free status for energy purchases | $407 | $250 |
$89
-
kWh
|
$318
-
MMBtu
|
- | |
09 | 2.7261: Install timers and/or thermostats | $360 | $600 |
$120
5,569
kWh
|
$240
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $11,802 | $11,380 |
$3,514
50,996
kWh
|
$1,588
-
MMBtu
|
$6,700
-
MMBtu
|
||
TOTAL IMPLEMENTED | $4,982 | $4,520 |
$2,894
42,497
kWh
|
$2,088
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Other Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs