| Assessment Year | 1990 |
|---|---|
| Principal Product | PRINTED CIRCUIT BOARDS |
| NAICS |
n/a
|
| SIC | 3672: Printed Circuit Boards |
| Sales Range | $1 M to 5M |
| # of Employees | 47 |
| Plant Area |
n/a
|
| Annual Production | 175,000
pieces
|
| Production Hrs. Annual | 4,628
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $37,993 | 495,897 |
kWh
|
$0.077 |
| Natural Gas | $2,969 | 744 |
MMBtu
|
$3.99 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $5,960 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,660 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $3,300 | $500 |
$3,300
-
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,010 | $220 |
$1,010
13,189
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $70 | $190 |
$70
879
kWh
|
- | |
| 04 | 2.7261: Install timers and/or thermostats | $910 | $800 |
$540
20,809
kWh
|
$370
-
MMBtu
|
|
| 05 | 2.2511: Insulate bare equipment | $460 | $200 |
$460
6,155
kWh
|
- | |
| 06 | 2.2514: Cover open tanks | $210 | $400 |
$210
2,931
kWh
|
- | |
| TOTAL RECOMMENDED | $5,960 | $2,310 |
$5,590
43,963
kWh
|
$370
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $2,660 | $1,810 |
$2,290
43,963
kWh
|
$370
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs