Assessment Year | 1990 |
---|---|
Principal Product | INJECTION MOLDED PARTS |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 50 |
Plant Area |
n/a
|
Annual Production | 100,000
pieces
|
Production Hrs. Annual | 6,480
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $34,379 | 663,247 |
kWh
|
$0.052 |
Natural Gas | $2,812 | 662 |
MMBtu
|
$4.25 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $3,068 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,068 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $758 | $524 |
$758
14,654
kWh
|
- | |
02 | 2.8121: Apply for tax-free status for energy purchases | $1,070 | $250 |
$1,004
-
kWh
|
$66
-
MMBtu
|
|
03 | 2.6223: Schedule use of elevators to conserve energy | $420 | $300 |
$420
8,206
kWh
|
- | |
04 | 2.2443: Re-use or recycle hot or cold process exhaust air | $340 | $600 | - |
$340
-
MMBtu
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $300 | $880 |
$300
5,862
kWh
|
- | |
06 | 2.6232: Install set-back timers | $180 | $100 |
$180
3,517
kWh
|
- | |
TOTAL RECOMMENDED | $3,068 | $2,654 |
$2,662
32,239
kWh
|
$406
-
MMBtu
|
||
TOTAL IMPLEMENTED | $3,068 | $2,654 |
$2,662
32,239
kWh
|
$406
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs