Assessment Year | 1990 |
---|---|
Principal Product | POLYURETHANE COATINGS |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 15 |
Plant Area |
n/a
|
Annual Production | 260,000
lb
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $30,561 | 584,994 |
kWh
|
$0.052 |
Natural Gas | $25,244 | 5,947 |
MMBtu
|
$4.24 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $6,117 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,795 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $2,837 | $200 |
$1,543
-
kWh
|
$1,294
-
MMBtu
|
|
02 | 2.4131: Size electric motors for peak operating efficiency | $300 | $200 |
$300
5,862
kWh
|
- | |
03 | 2.7261: Install timers and/or thermostats | $1,290 | $50 |
$540
10,258
kWh
|
$750
-
MMBtu
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $288 | $339 |
$288
5,862
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $80 | $177 |
$80
1,465
kWh
|
- | |
06 | 2.7243: Improve air circulation with destratification fans / other methods | $1,322 | $3,600 |
$(-38.0)
(-586)
kWh
|
$1,360
-
MMBtu
|
|
TOTAL RECOMMENDED | $6,117 | $4,566 |
$2,713
22,861
kWh
|
$3,404
-
MMBtu
|
||
TOTAL IMPLEMENTED | $4,795 | $966 |
$2,751
23,447
kWh
|
$2,044
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs