| Assessment Year | 1989 |
|---|---|
| Principal Product | DENTAL EQUIPMENT COMPONENTS |
| NAICS |
n/a
|
| SIC | 3843: Dental Equipment and Supplies |
| Sales Range | $5 M to 10M |
| # of Employees | 75 |
| Plant Area |
n/a
|
| Annual Production | 1,000,000
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $42,941 | 682,298 |
kWh
|
$0.063 |
| Natural Gas | $8,334 | 2,051 |
MMBtu
|
$4.06 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $8,215 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,025 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4131: Size electric motors for peak operating efficiency | $1,460 | $4,500 |
$1,460
23,154
kWh
|
- | |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $580 | - |
$580
9,379
kWh
|
- | |
| 03 | 2.1123: Install automatic stack damper | $800 | $1,400 | - |
$800
-
MMBtu
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $920 | $372 |
$920
14,654
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,510 | $372 |
$1,510
24,033
kWh
|
- | |
| 06 | 2.6232: Install set-back timers | $730 | $800 |
$730
11,723
kWh
|
- | |
| 07 | 2.8121: Apply for tax-free status for energy purchases | $215 | $250 | - |
$215
-
MMBtu
|
|
| 08 | 2.2511: Insulate bare equipment | $1,520 | $1,000 |
$1,520
24,326
kWh
|
- | |
| 09 | 2.2443: Re-use or recycle hot or cold process exhaust air | $480 | $400 | - |
$480
-
MMBtu
|
|
| TOTAL RECOMMENDED | $8,215 | $9,094 |
$6,720
107,269
kWh
|
$1,495
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $6,025 | $3,794 |
$4,530
72,392
kWh
|
$1,495
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs