Assessment Year 1989
Principal Product REFINED CADMIUM INGOTS
NAICS
n/a
SIC 3339: Primary Smelting and Refining of Nonferrous Metals, Except Copper and Aluminum
Sales Range $10
M
to 50
M
# of Employees 70
Plant Area
n/a
Annual Production 1,080,000
lb
Production Hrs. Annual 8,736
hrs
Location (State) Colorado

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $167,182 3,427,022
kWh
Natural Gas $210,170 59,783
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $46,299 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $43,755

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.8113: Purchase gas directly from a contract gas supplier $33,200 $6,700 - $33,200
-
MMBtu
02 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $1,410 $5,000 $1,410
38,101
kWh
-
03 2.2511: Insulate bare equipment $351 $3,460 - $351
-
MMBtu
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,887 $4,162 $2,887
59,203
kWh
-
05 2.2414: Use waste heat from hot flue gases to preheat $4,494 $2,200 - $4,494
-
MMBtu
06 2.2414: Use waste heat from hot flue gases to preheat $2,193 $10,000 - $2,193
-
MMBtu
07 2.1233: Analyze flue gas for proper air/fuel ratio $800 $700 - $800
-
MMBtu
08 2.7261: Install timers and/or thermostats $657 $750 - $657
-
MMBtu
09 2.7142: Utilize higher efficiency lamps and/or ballasts $307 $359 $307
6,448
kWh
-
TOTAL RECOMMENDED $46,299 $33,331 $4,604
103,752
kWh
$41,695
-
MMBtu
TOTAL IMPLEMENTED $43,755 $19,871 $4,604
103,752
kWh
$39,151
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs