| Assessment Year | 1987 |
|---|---|
| Principal Product | PORK PRODUCTS |
| NAICS |
n/a
|
| SIC | 2011: Meat Packing Plants |
| Sales Range | $5 M to 10M |
| # of Employees | 55 |
| Plant Area |
n/a
|
| Annual Production | 37,000,000
lb
|
| Production Hrs. Annual | 0
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $149,687 | 2,713,072 |
kWh
|
$0.055 |
| Natural Gas | $85,082 | 21,771 |
MMBtu
|
$3.91 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $27,814 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $13,760 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,958 | $300 | - |
$2,958
-
MMBtu
|
|
| 02 | 2.2135: Repair and eliminate steam leaks | $805 | $900 | - |
$805
-
MMBtu
|
|
| 03 | 2.2447: Heat water with exhaust heat | $9,892 | $20,200 | - |
$9,892
-
MMBtu
|
|
| 04 | 2.2425: Use flue gases to heat process or service water | $1,768 | $4,000 | - |
$1,768
-
MMBtu
|
|
| 05 | 2.2136: Install / repair insulation on steam lines | $2,151 | $3,488 | - |
$2,151
-
MMBtu
|
|
| 06 | 2.2511: Insulate bare equipment | $467 | $2,300 | - |
$467
-
MMBtu
|
|
| 07 | 2.7261: Install timers and/or thermostats | $622 | $25 | - |
$622
-
MMBtu
|
|
| 08 | 2.7229: Air condition only space necessary | $766 | $500 |
$766
13,775
kWh
|
- | |
| 09 | 2.4221: Install compressor air intakes in coolest locations | $94 | $200 |
$94
1,758
kWh
|
- | |
| 10 | 2.8121: Apply for tax-free status for energy purchases | $7,224 | $250 |
$7,224
-
kWh
|
- | |
| 11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,067 | $606 |
$1,067
19,343
kWh
|
- | |
| TOTAL RECOMMENDED | $27,814 | $32,769 |
$9,151
34,876
kWh
|
$18,663
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $13,760 | $4,963 |
$7,224
-
kWh
|
$6,536
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs