Assessment Year 1987
Principal Product AGRICULTURAL EQUIPMENT
NAICS
n/a
SIC 3523: Farm Machinery and Equipment
Sales Range $10
M
to 50
M
# of Employees 400
Plant Area
n/a
Annual Production 5,000
pieces
Production Hrs. Annual 4,160
hrs
Location (State) Nebraska

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $227,020 7,592,907
kWh
Natural Gas $376,574 84,204
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $126,125 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $51,471

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.6212: Turn off equipment during breaks, reduce operating time $2,416 $21 $42
1,465
kWh
$2,374
-
MMBtu
02 2.2532: Use only amount of air necessary to prevent explosion hazard $2,026 $150 - $2,026
-
MMBtu
03 2.6212: Turn off equipment during breaks, reduce operating time $6,537 $500 - $6,537
-
MMBtu
04 2.2531: Re-size charging openings or add movable cover or door $8,540 $3,000 - $8,540
-
MMBtu
05 2.6212: Turn off equipment during breaks, reduce operating time $726 $300 - $726
-
MMBtu
06 2.7261: Install timers and/or thermostats $13,198 - - $13,198
-
MMBtu
07 2.7231: Use radiant heater for spot heating $50,245 $180,000 - $50,245
-
MMBtu
08 2.7243: Improve air circulation with destratification fans / other methods $19,113 $24,000 $(-916.0)
(-30,774)
kWh
$20,029
-
MMBtu
09 2.7229: Air condition only space necessary $8,911 $2,100 - $8,911
-
MMBtu
10 2.7492: Use proper thickness of insulation on building envelope $3,042 $7,140 - $3,042
-
MMBtu
11 2.7492: Use proper thickness of insulation on building envelope $3,916 $13,440 - $3,916
-
MMBtu
12 2.6212: Turn off equipment during breaks, reduce operating time $3,066 $750 $3,066
165,006
kWh
-
13 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,437 $1,000 $2,437
81,477
kWh
-
14 2.2437: Recover waste heat from equipment $1,473 $750 - $1,473
-
MMBtu
15 2.4221: Install compressor air intakes in coolest locations $479 $300 $479
16,120
kWh
-
TOTAL RECOMMENDED $126,125 $233,451 $5,108
233,294
kWh
$121,017
-
MMBtu
TOTAL IMPLEMENTED $51,471 $27,771 $5,108
233,294
kWh
$46,363
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs