Assessment Year 1987
Principal Product ROCKET ASSEMBLIES
NAICS
n/a
SIC 3769: Guided Missile Space Vehicle Parts and Auxiliary Equipment, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 100
Plant Area
n/a
Annual Production 39,000
pieces
Production Hrs. Annual 5,200
hrs
Location (State) Colorado

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $118,072 2,050,117
kWh
Natural Gas $82,329 19,226
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $57,032 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $21,346

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.1233: Analyze flue gas for proper air/fuel ratio $2,886 $2,200 - $2,886
-
MMBtu
02 2.6218: Turn off equipment when not in use $799 $700 - $799
-
MMBtu
03 2.2136: Install / repair insulation on steam lines $1,180 $1,020 - $1,180
-
MMBtu
04 2.7221: Lower temperature during the winter season and vice-versa $9,431 $3,200 - $9,431
-
MMBtu
05 2.7243: Improve air circulation with destratification fans / other methods $4,852 $5,000 $(-442.0)
(-7,620)
kWh
$5,294
-
MMBtu
06 2.7312: Minimize use of outside make-up air for ventilation except when used for economizer cycle $13,610 $30,000 $(-1,398.0)
(-24,326)
kWh
$15,008
-
MMBtu
07 2.7231: Use radiant heater for spot heating $11,670 $40,000 - $11,670
-
MMBtu
08 2.4221: Install compressor air intakes in coolest locations $982 $500 $982
16,999
kWh
-
09 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,794 $500 $3,794
65,944
kWh
-
10 2.1311: Replace electrically-operated equipment with fossil fuel equipment $3,575 $6,500 $4,728
63,306
kWh
$(-1,153.0)
-
MMBtu
11 2.3191: Use demand controller or load shedder $2,380 $2,000 $2,380
-
kWh
-
12 2.7142: Utilize higher efficiency lamps and/or ballasts $1,873 $720 $1,873
32,532
kWh
-
TOTAL RECOMMENDED $57,032 $92,340 $11,917
146,835
kWh
$45,115
-
MMBtu
TOTAL IMPLEMENTED $21,346 $9,120 $9,029
115,475
kWh
$12,317
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs