ITAC Assessment: CO0003
ITAC logo
ITAC Assessment: CO0003
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1984
Principal Product MILK,SOUR CREAM,ICE CREAM
NAICS
n/a
SIC 2026: Fluid Milk
Sales Range $1
M
to 5
M
# of Employees 30
Plant Area
n/a
Annual Production 6,600,000
lb
Production Hrs. Annual 2,860
hrs
Location (State) Colorado

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $31,284 557,151
kWh
Natural Gas $17,714 4,169
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $13,990 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $13,990

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.1233: Analyze flue gas for proper air/fuel ratio $5,060 $300 - $5,060
-
MMBtu
-
02 2.2414: Use waste heat from hot flue gases to preheat $1,272 $2,500 - $1,272
-
MMBtu
-
03 2.7111: Reduce illumination to minimum necessary levels $594 $118 $594
10,551
kWh
- -
04 2.1311: Replace electrically-operated equipment with fossil fuel equipment $1,430 $500 $2,130
37,808
kWh
$(-700.0)
-
MMBtu
-
05 2.1222: Install turbulators $1,594 $1,100 - $1,594
-
MMBtu
-
06 2.2437: Recover waste heat from equipment $435 $800 - $435
-
MMBtu
-
07 2.2711: Utilize outside air instead of conditioned air for drying $410 $300 $410
7,327
kWh
- -
08 2.2121: Increase amount of condensate returned $1,765 $1,494 - $1,055
-
MMBtu
$710
09 2.2136: Install / repair insulation on steam lines $1,045 $635 - $1,045
-
MMBtu
-
10 2.7441: Replace broken windows and/or window sash $385 $1,494 - $385
-
MMBtu
-
TOTAL RECOMMENDED $13,990 $9,241 $3,134
55,686
kWh
$10,146
-
MMBtu
$710
TOTAL IMPLEMENTED $13,990 $9,241 $3,134
55,686
kWh
$10,146
-
MMBtu
$710
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs