| Assessment Year | 2026 |
|---|---|
| Principal Product | Modular data center |
| NAICS | 332322: Sheet Metal Work Manufacturing |
| SIC | 3444: Sheet Metal Work |
| Sales Range | $10 M to 50M |
| # of Employees | 130 |
| Plant Area |
82,391
ft2
|
| Annual Production | 48
units
|
| Production Hrs. Annual | 5,900
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $29,829 | 774,699 |
kWh
|
$0.039 | |
| Electricity Demand | $67,655 | 2,639 |
kW-mo/yr
|
$25.64 | |
| Electricity Fees | $12,246 | - |
|
- | |
| Natural Gas | $153,150 | 10,411 |
MMBtu
|
$14.71 | |
| LPG | $11,355 | 171 |
MMBtu
|
$66.41 | |
| Waste Disposal Costs | |||||
| Water Usage | $3,064 | 399 |
Tgal
|
$7.68 | |
| TOTAL YEARLY COSTS | $277,298 | ||||
| RECOMMENDED SAVINGS* | $203,627 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | Other Gas Savings | Ancillary Material Cost Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 4.212: Adopt in-house material generation | $63,110 | $333,277 |
$(-4,920.0)
(-127,798)
kWh
|
$(-7,486.0)
-
kW-mo/yr
|
- | - | - | $75,516 | - | |
| 02 | 2.8114: Change rate schedules or other changes in utility service | $62,870 | - | - | - |
$(-76,757.5)
-
MMBtu
|
- |
$139,628
-
MMBtu
|
- | - | |
| 03 | 2.9114: Use solar heat to make electricty | $30,027 | $425,368 |
$21,422
556,367
kWh
|
$8,605
-
kW-mo/yr
|
- | - | - | - | - | |
| 04 | 3.1161: Eliminate/reduce an operation | $14,049 | $65,078 | - | - |
$13,598
-
MMBtu
|
- | - | - |
$451
-
Tgal
|
|
| 05 | 2.8121: Apply for tax-free status for energy purchases | $11,034 | $8,000 | - | - | - | - | - | $11,034 | - | |
| 06 | 2.8226: Increase efficiency of trucks | $8,418 | $64,500 |
$(-282.0)
(-7,320)
kWh
|
- | - |
$7,260
-
MMBtu
|
- | $1,440 | - | |
| 07 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $7,432 | $18,820 |
$342
8,879
kWh
|
- |
$7,090
-
MMBtu
|
- | - | - | - | |
| 08 | 2.7232: Replace existing hvac unit with high efficiency model | $3,020 | $30,050 |
$722
18,764
kWh
|
$2,298
-
kW-mo/yr
|
- | - | - | - | - | |
| 09 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $2,241 | $558 |
$463
12,029
kWh
|
$1,778
-
kW-mo/yr
|
- | - | - | - | - | |
| 10 | 2.6231: Utilize controls to operate equipment only when needed | $703 | $1,000 |
$703
18,260
kWh
|
- | - | - | - | - | - | |
| 11 | 2.2414: Use waste heat from hot flue gases to preheat | $530 | $4,200 | - | - |
$530
-
MMBtu
|
- | - | - | - | |
| 12 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $192 | $183 |
$67
1,730
kWh
|
$125
-
kW-mo/yr
|
- | - | - | - | - | |
| TOTAL RECOMMENDED | $203,627 | $951,034 |
$18,517
480,911
kWh
|
$5,320
-
kW-mo/yr
|
$(-55,539.5)
-
MMBtu
|
$7,260
-
MMBtu
|
$139,628
-
MMBtu
|
$87,990 |
$451
-
Tgal
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | Other Gas Savings | Ancillary Material Cost Savings | Water Consumption Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs