Assessment Year | 2021 |
---|---|
Principal Product | Injection Moulded Parts |
NAICS | 325211: Plastics Material and Resin Manufacturing |
SIC | 2821: Plastics Materials, Synthetic Resins, and Nonvulcanizable Elastomers |
Sales Range | $10 M to 50M |
# of Employees | 95 |
Plant Area |
75,000
ft2
|
Annual Production | 7,000,000
pieces
|
Production Hrs. Annual | 5,880
hrs
|
Location (State) | South Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $175,111 | 4,695,835 |
kWh
|
$0.037 | |
Electricity Demand | $162,050 | 11,967 |
kW-mo/yr
|
$13.54 | |
Electricity Fees | $463 | - |
|
- | |
Natural Gas | $1,675 | 176 |
MMBtu
|
$9.52 | |
Waste Disposal Costs | |||||
Water Usage | $3,550 | 636 |
Tgal
|
$5.58 | |
Water Disposal | $7,802 | 636 |
Tgal
|
$12.27 | |
TOTAL YEARLY COSTS | $350,651 | ||||
RECOMMENDED SAVINGS* | $28,654 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,199 | $12,730 |
$7,946
213,094
kWh
|
$6,253
-
kW-mo/yr
|
|
02 | 2.7135: Install occupancy sensors | $1,049 | $3,565 |
$1,049
28,122
kWh
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,596 | $2,100 |
$1,508
40,443
kWh
|
$88
-
kW-mo/yr
|
|
04 | 2.6211: Conserve energy by efficient use of vending machines | $182 | $520 |
$182
4,888
kWh
|
- | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $5,061 | $10,000 |
$5,061
135,693
kWh
|
- | |
06 | 2.7221: Lower temperature during the winter season and vice-versa | $5,453 | - |
$5,453
146,196
kWh
|
- | |
07 | 2.4239: Eliminate or reduce compressed air usage | $947 | - |
$375
10,043
kWh
|
$573
-
kW-mo/yr
|
|
08 | 2.7442: Keep doors and windows shut when not on use | $166 | - |
$166
4,456
kWh
|
- | |
TOTAL RECOMMENDED | $28,654 | $28,915 |
$21,741
582,935
kWh
|
$6,913
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs