Assessment Year 2021
Principal Product Injection Moulded Parts
NAICS 325211: Plastics Material and Resin Manufacturing
SIC 2821: Plastics Materials, Synthetic Resins, and Nonvulcanizable Elastomers
Sales Range $10
M
to 50
M
# of Employees 95
Plant Area 75,000
ft2
Annual Production 7,000,000
pieces
Production Hrs. Annual 5,880
hrs
Location (State) South Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $175,111 4,695,835
kWh
Electricity Demand $162,050 11,967
kW-mo/yr
Electricity Fees $463 -
Natural Gas $1,675 176
MMBtu
Waste Disposal Costs
Water Usage $3,550 636
Tgal
Water Disposal $7,802 636
Tgal
TOTAL YEARLY COSTS $350,651
RECOMMENDED SAVINGS* $28,654 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $14,199 $12,730 $7,946
213,094
kWh
$6,253
-
kW-mo/yr
02 2.7135: Install occupancy sensors $1,049 $3,565 $1,049
28,122
kWh
-
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,596 $2,100 $1,508
40,443
kWh
$88
-
kW-mo/yr
04 2.6211: Conserve energy by efficient use of vending machines $182 $520 $182
4,888
kWh
-
05 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $5,061 $10,000 $5,061
135,693
kWh
-
06 2.7221: Lower temperature during the winter season and vice-versa $5,453 - $5,453
146,196
kWh
-
07 2.4239: Eliminate or reduce compressed air usage $947 - $375
10,043
kWh
$573
-
kW-mo/yr
08 2.7442: Keep doors and windows shut when not on use $166 - $166
4,456
kWh
-
TOTAL RECOMMENDED $28,654 $28,915 $21,741
582,935
kWh
$6,913
-
kW-mo/yr
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs